1.
Appl Opt ; 63(10): 2694-2703, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568554

RESUMO

Accurate assessment of corneal curvatures using frequency domain optical coherence tomography (OCT) with galvanometer scanners remains challenging due to the well-known scan field distortion. This paper presents an algorithm and software for correcting the distortion using only two simple measurements in which a readily available standard sphere is positioned in different depths in front of the OCT scanner. This offers a highly accessible and easily reproducible method for the field distortion correction (FDC). The correction was validated by measuring different spherical phantoms and conducting corneal curvature measurements of ex vivo porcine corneas using a commercial spectral-domain OCT system and a clinically approved swept-source OCT as a reference instrument. Thus, the error in radius measurements of spherical phantoms was reduced by >90% and astigmatism by >80% using FDC. In explanted porcine eyes, the error in astigmatism measurements with the Telesto was reduced by 75% for power and 70% for angle. The best fitting sphere radius was determined up to a deviation of 0.4% from the Anterion. This paper describes a correction algorithm for OCT immanent distortion that is applicable to any scanning OCT setup and enables precise corneal curvature measurements. The MATLAB software for the FDC is publicly available on GitHub.


Assuntos
Astigmatismo , Tomografia de Coerência Óptica , Animais , Suínos , Algoritmos , Software , Córnea/diagnóstico por imagem
2.
Transl Vis Sci Technol ; 13(4): 13, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38587437

RESUMO

Purpose: To assess the efficacy of an automated program for keratoconus and keratoconus suspect detection based on corneal measurements provided by a combined Placido disc and anterior segment optical coherence tomography (OCT) topographer. Methods: In a multicentric cross-sectional study, an artificial neural network (ANN) was created using 6677 eyes from an equal number of patients (classified as 2663 normal eyes, 1616 keratoconus eyes, 210 keratoconus suspect eyes, 1519 myopic postoperative eyes, and 669 abnormal eyes). Each group was randomly divided into a training set (70% of the dataset) and a validation set (the remaining 30%). A multilayer perceptron network with a backpropagation learning algorithm was developed for the study. Indexes used to train the ANN were based on curvature and elevation of both the anterior and posterior corneal surfaces and the new corneal OCT indexes-based on corneal, stromal, and epithelial thicknesses. Results: For keratoconus detection, our ANN showed an accuracy of 98.6%, precision of 96%, recall of 97.9%, and F1-score of 96.9%. For keratoconus suspect detection, our ANN showed an accuracy of 98.5%, precision of 83.6%, recall of 69.7%, and F1-score of 76%. Conclusions: Compared to previous literature, the addition of new OCT-based epithelial and stromal thickness indexes improves ANN detection capacity of keratoconus suspect eyes. For already stablished keratoconus our ANN detection capacity is excellent, but equivalent to previous evidence without incorporating such new OCT-based indexes. Translational Relevance: OCT-based epithelial and stromal thickness indexes improve ANN detection capacity of keratoconus on its early stages.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico por imagem , Tomografia de Coerência Óptica , Estudos Transversais , Redes Neurais de Computação , Córnea/diagnóstico por imagem
3.
PLoS One ; 19(4): e0300576, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640111

RESUMO

PURPOSE: The purpose of this study was to investigate the effect of the corneal back surface by comparing the keratometric astigmatism (K, derived from the corneal front surface) of a modern optical biometer against astigmatism of Total Keratometry (TK, derived from both corneal surfaces) in a large population with cataractous eyes. The results were then used to define linear prediction models to map K to TK. METHODS: From a large dataset containing bilateral biometric measurements (IOLMaster 700) in 9736 patients prior to cataract surgery, the total corneal astigmatism was decomposed into vectors for K, corneal back surface (BS), and TK. A multivariate prediction model (MV), simplified model with separation of vector components (SM) and a constant model (CM) were defined to map K to TK vector components. RESULTS: The K centroid (X/Y) showed some astigmatism with-the-rule (0.1981/-0.0211 dioptre (dpt)) whereas the TK centroid was located around zero (-0.0071/-0.0381 dpt against-the-rule) and the BS centroid showed systematic astigmatism against-the-rule (-0.2367/-0.0145 dpt). The respective TK-K centroid was located at -0.2052/-0.0302 dpt. The MV model showed the same performance (i.e. mean absolute residuum) as the SM did (0.1098 and 0.1099 dpt respectively) while the CM performed only slightly worse (0.1121 dpt mean absolute residuum). CONCLUSION: In cases where tomographic data are unavailable statistical models could be used to consider the overall contribution of the back surface to the total corneal astigmatism. Since the performance of the CM is sufficiently close to that of MV and SM we recommend using the CM which can be directly considered e.g. as surgically induced astigmatism.


Assuntos
Astigmatismo , Extração de Catarata , Doenças da Córnea , Humanos , Astigmatismo/diagnóstico , Biometria/métodos , Córnea/diagnóstico por imagem
4.
BMC Ophthalmol ; 24(1): 138, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38539111

RESUMO

PURPOSE: To assess the level of agreement and evaluate the reliability of measurements between two Scheimpflug imaging modalities, Scansys (MediWorks, China) and Sirius (CSO, Italy), in quantifying the anterior segment parameters in healthy eyes. METHODS: In a cross-sectional study, the right eyes of 38 healthy participants without any ocular or systemic diseases were examined. A range of anterior segment parameters including anterior and posterior flat and steep keratometry, central corneal thickness (CCT), thinnest corneal thickness (TCT), anterior chamber depth (ACD), anterior chamber angle (ACA), corneal volume, anterior chamber volume, and horizontal white to white diameter, derived from the sagittal curvature maps were measured. To evaluate the reliability of the measurements, intraclass correlation coefficient (ICC) and correlation coefficient were measured. Additionally, Bland-Altman plots were employed to examine the agreement in mean (bias line) and 95% limits of agreement between the two devices. RESULTS: The mean age was 31.5 ± 6.9 (range: 19-47) years. The ICC indicated that the majority of anterior segment parameters had an excellent or good level of reliability, surpassing the threshold of 0.9. Nevertheless, CCT and ACA exhibited a moderate level of reliability, with ICC values of 0.794 and 0.728, respectively. The correlation analysis showed a strong correlation for all the variables tested. The Bland-Altman plots revealed that the bias line was near zero and the 95% limits of agreement were narrow for most variables, except for the anterior flat and steep keratometry, which were found to range from - 0.57 to 0.84 D and - 0.68 to 0.87 D, respectively. CONCLUSION: Scansys and Sirius devices can be effectively used interchangeably for the evaluation of most anterior segment parameters; however, for anterior corneal curvatures, CCT and ACA, their alternative use is not recommended.


Assuntos
Córnea , Tomografia , Humanos , Adulto Jovem , Adulto , Reprodutibilidade dos Testes , Estudos Transversais , Estudos Prospectivos , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Tomografia de Coerência Óptica
5.
Comput Biol Med ; 172: 108286, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38493602

RESUMO

PURPOSE: To ascertain whether the integration of raw Corvis ST data with an end-to-end CNN can enhance the diagnosis of keratoconus (KC). METHOD: The Corvis ST is a non-contact device for in vivo measurement of corneal biomechanics. The CorNet was trained and validated on a dataset consisting of 1786 Corvis ST raw data from 1112 normal eyes and 674 KC eyes. Each raw data consists of the anterior and posterior corneal surface elevation during air-puff induced dynamic deformation. The architecture of CorNet utilizes four ResNet-inspired convolutional structures that employ 1 × 1 convolution in identity mapping. Gradient-weighted Class Activation Mapping (Grad-CAM) was adopted to visualize the attention allocation to diagnostic areas. Discriminative performance was assessed using metrics including the AUC of ROC curve, sensitivity, specificity, precision, accuracy, and F1 score. RESULTS: CorNet demonstrated outstanding performance in distinguishing KC from normal eyes, achieving an AUC of 0.971 (sensitivity: 92.49%, specificity: 91.54%) in the validation set, outperforming the best existing Corvis ST parameters, namely the Corvis Biomechanical Index (CBI) with an AUC of 0.947, and its updated version for Chinese populations (cCBI) with an AUC of 0.963. Though the ROC curve analysis showed no significant difference between CorNet and cCBI (p = 0.295), it indicated a notable difference between CorNet and CBI (p = 0.011). The Grad-CAM visualizations highlighted the significance of corneal deformation data during the loading phase rather than the unloading phase for KC diagnosis. CONCLUSION: This study proposed an end-to-end CNN approach utilizing raw biomechanical data by Corvis ST for KC detection, showing effectiveness comparable to or surpassing existing parameters provided by Corvis ST. The CorNet, autonomously learning comprehensive temporal and spatial features, demonstrated a promising performance for advancing KC diagnosis in ophthalmology.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea , Córnea/diagnóstico por imagem , Curva ROC , Fenômenos Biomecânicos
6.
Vestn Oftalmol ; 140(1): 5-10, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450460

RESUMO

Marfan syndrome (MS) is an orphan hereditary connective tissue disease associated with a mutation in the FBN1 gene, which pathological manifestations are characterized by polysystemic involvement. The fibrillin-1 protein is an integral component of the sclera and cornea of the eye, and in MS its structure is distrubed. PURPOSE: This study assesses potential structural and functional changes in the cornea and sclera of a patient with MS. MATERIAL AND METHODS: Two groups were formed, comparable in the axial length of the eye and age: the main group - 19 patients (38 eyes) with a verified diagnosis of MS, and the control group - 24 patients (48 eyes) with myopia of varying degrees. The results obtained from MS patients were analyzed depending on the absence or presence of ectopia lentis. In addition to measuring the basic ophthalmological parameters (refraction, axial length, visual acuity), topographic keratometry, anterior segment optical coherence tomography, and ocular response analyzer were used for structural and functional assessment of the cornea and sclera. RESULTS: In MS there was a statistically significant increase in the radius of curvature and a decrease in corneal refraction in the central zone compared to the control group. There were no significant differences in central corneal thickness, but there was a significant decrease in the thickness of the sclera in the limbal zone compared to the control group. There were no statistically significant changes in corneal hysteresis and corneal resistance factor in MS. CONCLUSION: This study confirmed the previously obtained data on the tendency of the optical power to reliably decrease in MS (flattening of the cornea). This symptom can be considered as a compensatory factor affecting clinical refraction, while the decrease in the thickness of the sclera - as the main reason for aaxial length elongation in MS. There were no clear patterns of dependence of the changes in the cornea and sclera analyzed in this study on the presence or absence of ectopia lentis. Changes in the lens, perhaps, should be regarded only as one of the potential components of the ocular symptom complex in MS.


Assuntos
Ectopia do Cristalino , Síndrome de Marfan , Humanos , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Ectopia do Cristalino/diagnóstico , Ectopia do Cristalino/etiologia , Córnea/diagnóstico por imagem , Esclera/diagnóstico por imagem , Refração Ocular
7.
Vestn Oftalmol ; 140(1): 86-92, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450471

RESUMO

Deep anterior lamellar keratoplasty or penetrating keratoplasty are currently considered the optimal methods of surgical treatment of stromal dystrophies and corneal degeneration. Despite certain advantages and benefits of these methods, they also have significant limitations: involvement of superficial corneal layers in the surgery, need for suturing, development of post-keratoplasty astigmatism etc. PURPOSE: This study aimed to test and describe the new method of closed sutureless keratoplasty (intracorneal selective stromal transplantation), which was indicated in isolated dystrophic and degenerative pathology of the stroma. MATERIAL AND METHODS: Intracorneal selective stromal transplantation was performed in a 62-year-old patient with stromal degeneration and intact corneal layers between the altered stroma and the Descemet's membrane posteriorly, and the Bowman's layer anteriorly. The patient also had immature senile cataract. Corneal stroma was removed and replaced with a graft in the optical center of the lens, while the endothelium, the Descemet's membrane and the Bowman's layer remained intact. RESULTS: The proposed technique of intracorneal selective stromal transplantation makes it possible to replace only the pathologically altered stroma through closed surgical approach, without affecting the anterior and posterior surfaces of the cornea. Best-corrected visual acuity has increased in the patient from 0.01 to 0.6, while mean endothelial cell density has not changed in the course of 24-months follow-up. CONCLUSION: The proposed keratoplasty method can be used in patients with dystrophy or degeneration of the corneal stroma and preserved endothelial cells, intact Descemet's membrane and Bowman layer. Since the superficial corneal layers are not involved during the surgery, intracorneal selective stromal transplantation combined the advantages of both deep anterior lamellar keratoplasty and endothelial keratoplasty. The biologically favorable result in this first clinical case allows a preliminary conclusion on the technical possibility and functional effectiveness of the proposed method, but further long-term observation and more clinical cases are required.


Assuntos
Catarata , Distrofias Hereditárias da Córnea , Transplante de Córnea , Humanos , Pessoa de Meia-Idade , Córnea/diagnóstico por imagem , Córnea/cirurgia , Células Endoteliais , Ceratoplastia Penetrante
8.
J AAPOS ; 28(2): 103863, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458600

RESUMO

PURPOSE: To investigate the correlation between swept-source anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in congenital corneal opacity (CCO). METHODS: All children with unilateral or bilateral congenital corneal opacities who underwent examination under anesthesia (EUA) and anterior segment optical coherence tomography (AS-OCT) imaging from January 1, 2022, to December 31, 2022, were included. Main outcome measures were corneal and anterior segment evaluation and correlation of UBM and AS-OCT findings. RESULTS: A total of 22 eyes of 15 patients were imaged using both technologies. The age at first EUA ranged from 11 days to 4 years. Different phenotypes were classified based on the clinical examination, UBM, and AS-OCT findings. Fourteen eyes were diagnosed with Peters anomaly, congenital corneal staphyloma was observed in 4 eyes, 2 eyes had coloboma, 1 eye had peripheral sclerocornea, and 1 eye was diagnosed with congenital primary aphakia. AS-OCT and UBM findings were closely correlated in 18 of 22 eyes (82%) but AS-OCT failed to provide detailed information in 4 eyes (18%) where UBM revealed more details. CONCLUSIONS: Although AS-OCT offers valuable preliminary data for initial assessment and counseling, it may not consistently provide precise assessments in all cases. Therefore, UBM should be considered for definitive evaluation.


Assuntos
Opacidade da Córnea , Microscopia Acústica , Criança , Humanos , Recém-Nascido , Microscopia Acústica/métodos , Tomografia de Coerência Óptica/métodos , Opacidade da Córnea/diagnóstico por imagem , Segmento Anterior do Olho/diagnóstico por imagem , Córnea/diagnóstico por imagem
10.
Sensors (Basel) ; 24(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38400392

RESUMO

In this paper, we present and evaluate a calibration-free mobile eye-traking system. The system's mobile device consists of three cameras: an IR eye camera, an RGB eye camera, and a front-scene RGB camera. The three cameras build a reliable corneal imaging system that is used to estimate the user's point of gaze continuously and reliably. The system auto-calibrates the device unobtrusively. Since the user is not required to follow any special instructions to calibrate the system, they can simply put on the eye tracker and start moving around using it. Deep learning algorithms together with 3D geometric computations were used to auto-calibrate the system per user. Once the model is built, a point-to-point transformation from the eye camera to the front camera is computed automatically by matching corneal and scene images, which allows the gaze point in the scene image to be estimated. The system was evaluated by users in real-life scenarios, indoors and outdoors. The average gaze error was 1.6∘ indoors and 1.69∘ outdoors, which is considered very good compared to state-of-the-art approaches.


Assuntos
Movimentos Oculares , Fixação Ocular , Tecnologia de Rastreamento Ocular , Córnea/diagnóstico por imagem , Algoritmos
11.
Transl Vis Sci Technol ; 13(2): 15, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38376862

RESUMO

Purpose: Validation of the feasibility of novel acoustic radiation force optical coherence elastography (ARF-OCE) for the evaluation of biomechanical enhancement of the in vivo model of keratoconus by clinical cross-linking (CXL) surgery. Methods: Twelve in vivo rabbit corneas were randomly divided into two groups. Both groups were treated with collagenase type II, and a keratoconus model was obtained. Then, the two groups were treated with CXL procedures with different irradiation energy of 15 J and 30 J (CXL-15 J and CXL-30 J, respectively). An ARF-OCE probe with an ultrasmall ultrasound transducer was used to detect the biomechanical properties of cornea. An antisymmetric Lamb wave model was combined with the frequency dispersion relationship to achieve depth-resolved elastography. Results: Compared with the phase velocity of the Lamb wave in healthy corneas (approximately 3.96 ± 0.27 m/s), the phase velocity of the Lamb wave was lower in the keratoconus region (P < 0.05), with an average value of 3.12 ± 0.12 m/s. Moreover, the corneal stiffness increased after CXL treatment (P < 0.05), and the average phase velocity of the Lamb wave was 4.3 ± 0.19 m/s and 4.54 ± 0.13 m/s after CXL-15 J and CXL-30 J treatment. Conclusions: The Young's moduli of the keratoconus regions were significantly lower than the healthy corneas. Moreover, the Young's modulus of the keratoconus regions was significantly higher after CXL-30 J treatment than after CXL-15 J treatment. We demonstrated that the ARF-OCE technique has great potential in screening keratoconus and guiding clinical CXL treatment. Translational Relevance: This work accelerates the clinical translation of OCE systems using ultrasmall ultrasound transducers and is used to guide CXL procedures.


Assuntos
Técnicas de Imagem por Elasticidade , Ceratocone , Animais , Coelhos , Ceratocone/diagnóstico por imagem , Ceratocone/tratamento farmacológico , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Córnea/cirurgia , Módulo de Elasticidade
12.
Eye Contact Lens ; 50(3): 121-125, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38345011

RESUMO

PURPOSE: Determine the pediatric prevalence of keratoconus (KC) using Scheimpflug corneal tomography. METHODS: A prospective observational study was done on subjects aged 3 to 18 years at the Princeton Vision Clinic, Chicago, IL. Scheimpflug tomography (Pentacam HR, OCULUS Optikgerate GmbH) scans (Belin/Ambrósio Enhanced Ectasia BAD3) yielded BAD Final D (Final D) and Back Elevation at the Thinnest Point (BETP) measurements. Criteria differentiating non-KC from KC suspects & KC were, Non-KC -Final D <2.00 in both eyes; KC suspect -Final D ≥2.00 and <3.00 in combination with BETP ≥18 µm for myopia and ≥28 µm for hyperopia/mixed astigmatism in at least one eye; and KC -Final D of ≥3.00 with BETP ≥18 µm for myopia or ≥28 µm for hyperopia/mixed astigmatism in at least one eye. Two thousand two hundred and six subjects were recorded, removing duplicate and poor-quality scans leaving 2007 subjects. RESULTS: Of 2007 subjects, six were classified as KC -prevalence of 1:334, three subjects were KC suspects -prevalence of 1:669, and total prevalence of KC suspects and KC was 1:223. CONCLUSION: The prevalence of KC in children is higher than previously reported, emphasizing the importance of sensitive screening for KC at its earliest manifestation as standard in pediatric comprehensive eye examinations.


Assuntos
Astigmatismo , Hiperopia , Ceratocone , Miopia , Criança , Humanos , Chicago/epidemiologia , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Miopia/diagnóstico , Miopia/epidemiologia , Prevalência , Curva ROC , Tomografia , Estudos Prospectivos
13.
J Fr Ophtalmol ; 47(4): 104096, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38382278

RESUMO

PURPOSE: To describe the biometric and corneal characteristics of patients with Marfan Syndrome (MFS) and ectopia lentis. STUDY DESIGN: Observational, descriptive, prospective study. Subjects Individuals with MFS with ectopia lentis (EL). METHODS: Fourty-four eyes of 23 patients underwent Scheimpflug analysis using the Pentacam (Oculus, Wetzlar, Germany), axial length (AL) using the IOL master 700 (Carl Zeiss AG, Oberkochen, Germany), endothelial cell count (ECC) using the CEM-350 (NIDEK, Maihama, Japan) and corneal biomechanics evaluation with the Ocular Response Analyzer: ORA (Reichert Ophthalmic Instruments, Buffalo, New York, USA) and Corvis (Oculus, Wetzlar, Germany). Statistical analysis was performed using IBM SPSS Statistics 25.0. RESULTS: The direction of lens subluxation was most frequently supero-nasal 40.9% (18/44). Mean keratometry (Km) was 40.22±1.76 Diopters (D); mean corneal astigmatism was 1.68±0.83 D; total corneal aberrometric root mean square (RMS) was 2.237±0.795µm; higher-order aberrations (HOAs) RMS were 0.576±0.272µm; mean AL was 25.63±3.65mm; mean ECC was 3315±459cell/mm2; mean CBI was 0.13±0.24, mean TBI was 0.31±0.25, mean posterior elevation was 4.3±4.5µm; mean total corneal densitometry was 16.0±2.14 grayscale units (GSU). CONCLUSION: Increased axial length, flatter and thicker corneas with higher regular astigmatism, normal densitometry, normal corneal biomechanical indices and normal posterior elevation were observed in Marfan patients with EL.


Assuntos
Astigmatismo , Ectopia do Cristalino , Síndrome de Marfan , Humanos , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Ectopia do Cristalino/diagnóstico , Ectopia do Cristalino/epidemiologia , Ectopia do Cristalino/etiologia , Estudos Prospectivos , Acuidade Visual , Córnea/diagnóstico por imagem , Biometria
14.
Sci Rep ; 14(1): 2124, 2024 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267485

RESUMO

The presence of corneal vascularization (CV) interferes with the angiogenic and immune privilege of the cornea, risking rejection in eyes following keratoplasty. Pre-operative (lymph)-angioregression is a promising therapeutic approach, but objective monitoring by non-invasive CV imaging is needed. The purpose of this study was to investigate anterior-segment optical coherence tomography angiography (AS-OCTA) for CV visualization and quantification, and to show its superiority over slit-lamp photography in high-risk eyes scheduled for keratoplasty. This institutional pilot study included 29 eyes of 26 patients (51 ± 16 years, 8 female) with significant CV scheduled for keratoplasty that were imaged by slit-lamp photography (Zeiss SL 800) and AS-OCTA (Zeiss Plex Elite 9000). After manual corneal layer segmentation correction, CV maximum/relative depth was measured with the inbuilt software. Slit-lamp photographs and AS-OCTA images were compared for visualization of vascular details. Angiotool software allowed a semi-automated determination of CV-related parameters in the vascular complex of AS-OCTA images. The predominant causes of CV were the herpes simplex virus keratitis (n = 7) and chemical burn (n = 4). Visualization of vascular morphology in AS-OCTA was superior to slit-lamp photography in all except one eye. Vascular metrics including total vessel length, number of junctions/endpoints, junction density, lacunarity, and vessel area/density were defined using Angiotool, with CV depth localization despite scarring and opacification. AS-OCTA proved effective for angioregressive treatment monitoring. AS-OCTA enables non-invasive and objective three-dimensional visualization of corneal vascularization superior to slit-lamp photography, and could be a precious tool for monitoring angioregressive preconditioning prior to keratoplasty.


Assuntos
Neovascularização da Córnea , Tomografia de Coerência Óptica , Humanos , Feminino , Projetos Piloto , Neovascularização da Córnea/diagnóstico por imagem , Córnea/diagnóstico por imagem , Angiografia
15.
J Biophotonics ; 17(4): e202300441, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38221644

RESUMO

Quantifying corneal elasticity after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) procedure plays an important role in improving surgical safety and quality, since some latent complications may occur ascribing to changes in postoperative corneal biomechanics. Nevertheless, it is suggested that current research has been severely constrained due to the lack of an accurate quantification method to obtain postoperative corneal elasticity distribution. In this paper, an acoustic radiation force optical coherence elastography system combined with the improved phase velocity algorithm was utilized to realize elasticity distribution images of the in vivo rabbit cornea after FS-LASIK under various intraocular pressure levels. As a result, elasticity variations within and between the regions of interest could be identified precisely. This is the first time that elasticity imaging of in vivo cornea after FS-LASIK surgery was demonstrated, and the results suggested that this technology may hold promise in further exploring corneal biomechanical properties after refractive surgery.


Assuntos
Técnicas de Imagem por Elasticidade , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Coelhos , Animais , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Lasers de Excimer , Córnea/diagnóstico por imagem , Córnea/cirurgia , Elasticidade
17.
Eye Contact Lens ; 50(3): 138-144, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38181218

RESUMO

OBJECTIVE: To compare the outcomes of corneal tomography obtained with an anterior-to-posterior segment optical coherence tomography device (Revo, Optopol Technologies Sp. z o.o.) and a rotating Scheimpflug camera (Pentacam AXL, Oculus Optikgeräte, Wetzlar, Germany). METHODS: In healthy subjects, agreement in stereometric parameters commonly used in cataract and refractive surgery was assessed. Comparison between the devices was performed using correlation coefficients, the Bland-Altman method, and a paired t test. RESULTS: Results of right eyes of 78 patients (47 women) aged 25.24±5.56 years were analyzed. The flat and steep anterior keratometry values were significantly higher for Revo than Pentacam (43.65±1.58 D vs. 42.99±1.47 D; P = 0.000, and 44.53±1.57 D vs. 43.82±1.49 D; P =0.000, respectively) and showed excellent correlation ( r =0.978 and 0.974, respectively). The results for maximal keratometry manifested a higher difference (45.89±1.69 D vs. 44.27±1.51 D for Revo and Pentacam, P =0.000) but were also strongly correlated ( r =0.871). Revo showed significantly lower corneal thickness values than Pentacam, both for apex pachymetry (535.54±32.45 vs. 550.74±31.55 µm; P =0.000) and for thinnest pachymetry (522.58±32.16 vs. 547.25±31.95 µm; P =0.000). The correlation coefficients for anterior and posterior corneal elevation at the thinnest point showed weak positive correlation ( r =0.179 and 0.185), while the correlation for corneal asphericity was moderate ( r =0.317). CONCLUSIONS: There was a significant difference between keratometric values obtained with Revo and the Pentacam AXL, although the measurements showed excellent correlation. Similar results were found for corneal thickness measurements, but not for corneal surface elevation and corneal asphericity.


Assuntos
Córnea , Tomografia de Coerência Óptica , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Estudos Prospectivos , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos
18.
Am J Ophthalmol ; 259: 185-196, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211780

RESUMO

PURPOSE: To analyze the corneal biomechanical properties in patients with abnormal corneal tomography (ACT) and predict their stability using the biomechanical stability index (BSI). DESIGN: Prospective cohort study. METHODS: Setting: Multicenter study. STUDY POPULATION: This study included 385 eyes of 278 patients with stable ACT (n = 70), subclinical keratoconus (SKC, n = 65), keratoconus (n = 65), normal controls (NL, n = 142). Forty-three eyes with first-visit ACT were included in a separate cohort (follow-up ACT group). OBSERVATION PROCEDURE: Tomographical and biomechanical parameters (Pentacam and Corvis ST) were recorded. MAIN OUTCOME MEASURES: Nonparametric tests were used for comparison. Logistic regression was employed to introduce BSI to separate stable ACT and SKC accurately. An independent dataset of 43 first-visit ACT eyes was followed up for 1 year to validate BSI's accuracy and positive and negative predictive values (PPV, NPV). RESULTS: The tomographical and biomechanical parameters in patients with Stable ACT remained stable over the follow-up period (12.73 ± 2.57 months, P > .05). Stable ACT had 12/14 biomechanical parameters different (P < .05) from SKC but not different from NL (P > .05). With a cut-off value of 0.585, BSI demonstrated the strongest ability to distinguish between stable ACT and SKC (area under the receiver operating characteristic curve = 0.991), with 93.85% sensitivity and 97.14% specificity. During the 1-year follow-up of 43 eyes (follow-up ACT group), 30 remained stable. The accuracy, PPV, and NPV of the BSI were 95.35%, 100%, and 93.75%, respectively. CONCLUSIONS: Biomechanical properties of patients with stable abnormal tomography corneas were stronger than SKC and close to normal corneas, which may explain the reason for tomographic stability. The BSI may be useful for predicting disease progression in patients with ACT and the possible management of corneal cross-linking at the first visit.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Estudos Prospectivos , Curva ROC , Prognóstico , Fenômenos Biomecânicos , Paquimetria Corneana/métodos
19.
J Biomed Opt ; 29(1): 016002, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38223300

RESUMO

Significance: The biomechanical impact of refractive surgery has long been an area of investigation. Changes to the cornea structure cause alterations to its mechanical integrity, but few studies have examined its specific mechanical impact. Aim: To quantify how the biomechanical properties of the cornea are altered by laser assisted in situ keratomileusis (LASIK) using optical coherence elastography (OCE) in ex vivo porcine corneas. Approach: Three OCE techniques, wave-based air-coupled ultrasound (ACUS) OCE, heartbeat (Hb) OCE, and compression OCE were used to measure the mechanical properties of paired porcine corneas, where one eye of the pair was left untreated, and the fellow eye underwent LASIK. Changes in stiffness as a function of intraocular pressure (IOP) before and after LASIK were measured using each technique. Results: ACUS-OCE showed that corneal stiffness changed as a function of IOP for both the untreated and the treated groups. The elastic wave speed after LASIK was lower than before LASIK. Hb-OCE and compression OCE showed regional changes in corneal strain after LASIK, where the absolute strain difference between the cornea anterior and posterior increased after LASIK. Conclusions: The results of this study suggest that LASIK may soften the cornea and that these changes are largely localized to the region where the surgery was performed.


Assuntos
Técnicas de Imagem por Elasticidade , Oftalmopatias , Ceratomileuse Assistida por Excimer Laser In Situ , Animais , Suínos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Córnea/cirurgia , Tonometria Ocular
20.
Cornea ; 43(5): 545-551, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38275916

RESUMO

PURPOSE: The aim of this study was to identify the risk factors for postkeratorefractive surgery ectasia in unsuspicious tomographies and to report a new index coined diameter of peak locations (DPLs). METHODS: All patients who underwent keratorefractive surgery between 2011 and 2018 at Care-Vision Laser Centers, Israel, and later developed ectasia were included. For each ectasia case, 3 matched controls were selected. Demographic and preoperative, intraoperative, and postoperative data were collected. Multivariate analysis was performed to evaluate the interdependence of the variables. RESULTS: The retrospective study included 19 ectasia and 58 control eyes. There were no significant differences between the groups in ablation depth ( P = 0.73), preoperative spherical equivalent ( P = 0.12), percent tissue altered ( P = 0.71), residual stromal bed ( P = 0.73), and Ectasia Risk Score System ( P = 0.60). The anterior and the posterior symmetry index were significantly higher ( P < 0.001), and DPL was significantly tighter in the ectasia group ( P = 0.01). Binary multiple logistic regression found the symmetry index of the posterior cornea and DPL to be better predictors than age, percent tissue altered, Ectasia Risk Score System, residual stromal bed, and ablation depth. CONCLUSIONS: A higher posterior symmetry index and a tighter DPL are predictors of ectasia in patients with otherwise normal tomographies. A tight DPL implies a weak area in the cornea, which is thin and slightly bulging, increasing the risk of this area becoming ectatic.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Humanos , Estudos Retrospectivos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Topografia da Córnea/métodos , Dilatação Patológica/etiologia , Dilatação Patológica/cirurgia , Complicações Pós-Operatórias/cirurgia , Córnea/diagnóstico por imagem , Córnea/cirurgia , Tomografia